Skip to Main Content
An official website of the United States government
Login Change: CDAS is now using the NIH Researcher Auth Service (RAS) to manage our existing login options. When logging into CDAS, you will be taken to RAS, where you can select your preferred login provider to access CDAS.

Influence of Accelerometer Calibration Approach on Moderate-Vigorous Physical Activity Estimates for Adults.

Authors

Matthews CE, Keadle SK, Berrigan D, Staudenmayer J, F Saint-Maurice P, Troiano RP, Freedson PS

Affiliations

  • Metabolic Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Bethesda, MD.
  • Behavioral Research Program, Division of Cancer Control and Population Sciences, National Cancer Institute, Bethesda, MD.
  • Department of Mathematics and Statistics, University of Massachusetts, Amherst, MA.
  • Risk Factor Assessment Branch, Division of Cancer Control and Population Sciences, National Cancer Institute, Bethesda, MD.
  • Department of Kinesiology, University of Massachusetts, Amherst, MA.

Abstract

PURPOSE: To compare estimates of moderate-vigorous physical activity (MVPA) duration derived from accelerometers calibrated only to walking and running activities to estimates from calibrations based on a broader range of lifestyle and ambulatory activities.

METHODS: In a study of 932 older (50-74 yr) adults we compared MVPA estimates from accelerometer counts based on three ambulatory calibration methods (Freedson 1952 counts per minute; Sasaki 2690 counts per minute; activPAL 3+ METs) to estimates based on calibrations from lifestyle and ambulatory activities combined (Matthews 760 counts per minute; Crouter 3+ METs; Sojourn3x 3+ METs). We also examined data from up to 6 previous-day recalls describing the MVPA in this population.

RESULTS: The MVPA duration values derived from ambulatory calibration methods were significantly lower than methods designed to capture a broader range of both lifestyle and ambulatory activities (P < 0.05). The MVPA (h·d) estimates in all participants were: Freedson (median, 0.35; interquartile range, 0.17-0.58); Sasaki (median, 0.91; interquartile range, 0.59-1.32); and activPAL (median, 0.97; interquartile range, 0.71-1.26) compared with Matthews (median, 1.82; interquartile range, 1.37-2.34); Crouter (2.28 [1.72-2.82]); and Sojourn3x (median, 1.85; interquartile range, 1.42-2.34). Recall-based estimates in all participants were comparable (median, 1.61; interquartile range, 0.89-2.57) and indicated participation in a broad range of lifestyle and ambulatory MVPA.

CONCLUSIONS: Accelerometer calibration studies that employ only ambulatory activities may produce MVPA duration estimates that are substantially lower than methods calibrated to a broader range of activities. These findings highlight the potential to reduce potentially large differences among device-based measures of MVPA due to variation in calibration study design by including a variety of lifestyle and ambulatory activities.