Measurement of Active and Sedentary Behavior in Context of Large Epidemiologic Studies.
Pubmed ID
28930863 (View this publication on the PubMed website)
Publication
Med Sci Sports Exerc. 2018 Feb; Volume 50 (Issue 2): Pages 266-276
Authors
Matthews CE, Kozey Keadle S, Moore SC, Schoeller DS, Carroll RJ, Troiano RP, Sampson JN
Affiliations
  • Metabolic Epidemiology Branch, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Rockville, MD.
Abstract

INTRODUCTION/PURPOSE: To assess the utility of measurement methods that may be more accurate and precise than traditional questionnaire-based estimates of habitual physical activity and sedentary behavior we compared the measurement properties of a past year questionnaire (AARP) and more comprehensive measures: an internet-based 24-h recall (ACT24), and a variety of estimates from an accelerometer (ActiGraph).

METHODS: Participants were 932 adults (50-74 yr) in a 12-month study that included reference measures of energy expenditure from doubly labeled water (DLW) and active and sedentary time via activPAL.

RESULTS: Accuracy at the group level (mean differences) was generally better for both ACT24 and ActiGraph than the AARP questionnaire. The AARP accuracy for energy expenditure ranged from -4% to -13% lower than DLW, but its accuracy was poorer for physical activity duration (-48%) and sedentary time (-18%) versus activPAL. In contrast, ACT24 accuracy was within 3% to 10% of DLW expenditure measures and within 1% to 3% of active and sedentary time from activPAL. For ActiGraph, accuracy for energy expenditure was best for the Crouter 2-regression method (-2% to -7%), and for active and sedentary time the 100 counts per minute cutpoint was most accurate (-1% to 2%) at the group level. One administration of the AARP questionnaire was significantly correlated with long-term average from the reference measures (ρTX = 0.16-0.34) overall, but four ACT24 recalls had higher correlations (ρTX = 0.48-0.60), as did 4 d of ActiGraph assessment (ρTX = 0.54-0.87).

CONCLUSIONS: New exposure assessments suitable for use in large epidemiologic studies (ACT24, ActiGraph) were more accurate and had higher correlations than a traditional questionnaire. Use of better more comprehensive measures in future epidemiologic studies could yield new etiologic discoveries and possibly new opportunities for prevention.

Related CDAS Studies