Skip to Main Content

An official website of the United States government

About this Publication
Title
Leveraging Serial Low-Dose CT Scans in Radiomics-based Reinforcement Learning to Improve Early Diagnosis of Lung Cancer at Baseline Screening.
Pubmed ID
38752718 (View this publication on the PubMed website)
Digital Object Identifier
Publication
Radiol Cardiothorac Imaging. 2024 Jun; Volume 6 (Issue 3): Pages e230196
Authors
Wang Y, Zhou C, Ying L, Lee E, Chan HP, Chughtai A, Hadjiiski LM, Kazerooni EA
Affiliations
  • From the Departments of Radiology (Y.W., C.Z., E.L., H.P.C., A.C., L.M.H., E.A.K.) and Internal Medicine (E.A.K.), The University of Michigan Medical School, 1500 E Medical Center Dr, Medical Inn Building, Rm C479, Ann Arbor, MI 48109-0904; Department of Electrical Engineering and Computer Science, The University of Michigan, Ann Arbor, Mich (Y.W., L.Y.); and Department of Diagnostic Radiology, Cleveland Clinic, Cleveland, Ohio (A.C.).
Abstract

Purpose To evaluate the feasibility of leveraging serial low-dose CT (LDCT) scans to develop a radiomics-based reinforcement learning (RRL) model for improving early diagnosis of lung cancer at baseline screening. Materials and Methods In this retrospective study, 1951 participants (female patients, 822; median age, 61 years [range, 55-74 years]) (male patients, 1129; median age, 62 years [range, 55-74 years]) were randomly selected from the National Lung Screening Trial between August 2002 and April 2004. An RRL model using serial LDCT scans (S-RRL) was trained and validated using data from 1404 participants (372 with lung cancer) containing 2525 available serial LDCT scans up to 3 years. A baseline RRL (B-RRL) model was trained with only LDCT scans acquired at baseline screening for comparison. The 547 held-out individuals (150 with lung cancer) were used as an independent test set for performance evaluation. The area under the receiver operating characteristic curve (AUC) and the net reclassification index (NRI) were used to assess the performances of the models in the classification of screen-detected nodules. Results Deployment to the held-out baseline scans showed that the S-RRL model achieved a significantly higher test AUC (0.88 [95% CI: 0.85, 0.91]) than both the Brock model (AUC, 0.84 [95% CI: 0.81, 0.88]; P = .02) and the B-RRL model (AUC, 0.86 [95% CI: 0.83, 0.90]; P = .02). Lung cancer risk stratification was significantly improved by the S-RRL model as compared with Lung CT Screening Reporting and Data System (NRI, 0.29; P < .001) and the Brock model (NRI, 0.12; P = .008). Conclusion The S-RRL model demonstrated the potential to improve early diagnosis and risk stratification for lung cancer at baseline screening as compared with the B-RRL model and clinical models. Keywords: Radiomics-based Reinforcement Learning, Lung Cancer Screening, Low-Dose CT, Machine Learning © RSNA, 2024 Supplemental material is available for this article.

Related CDAS Studies
Related CDAS Projects